A rhythmic clicking sound every 2 to 3 minutes indicates the compressor is trying to start, failing, and tripping its thermal overload switch. In approximately 70% of cases, the culprit is a burnt-out PTC start relay or defective run capacitor—a $150 to $250 repair. In the remaining 30%, the compressor's internal mechanical piston is seized.
What Causes the Loud Clicking Sound?
The compressor in your refrigerator operates like a heavy-duty single-phase electric motor. Because single-phase motors lack starting torque, they rely on a start winding engaged by a PTC (Positive Temperature Coefficient) relay or solid-state starter for the first fraction of a second.
When the start relay fails, the compressor motor cannot turn over. It draws massive locked-rotor amperage (LRA), heating up rapidly until the bimetal thermal overload protector snaps open with a distinct loud 'CLICK'. After cooling down for 2–3 minutes, the overload resets, clicks shut, tries again, and trips once more in an endless cycle.
Testing the PTC Start Relay vs. Compressor Windings
Before spending $1,500 on a new refrigerator, our Garland technicians perform an objective multimeter diagnosis:
| Component | Good Diagnostic Reading | Failed Reading | Action |
|---|---|---|---|
| PTC Start Relay | Continuity between terminals (3–12 Ω); no rattle | Infinite resistance (open) or rattles like broken glass when shaken | Replace start relay module ($120–$220) |
| Run Capacitor | Within ±5% of microfarad (µF) rating printed on case | Swollen plastic dome, oil leak, or 0 µF capacitance | Replace motor run capacitor ($95–$160) |
| Compressor Windings (Common to Start) | 3 to 10 Ω resistance | 0 Ω (shorted) or OL / Infinite Ω (open circuit) | Replace compressor or unit ($350–$650) |
| Compressor Windings to Ground | Infinite resistance (OL) from any pin to bare copper pipe | Any continuity (< 100k Ω) to chassis frame | Fatal electrical ground fault; unit is unsafe |
The 'Rattle Test': Unplug your refrigerator, remove the rear lower cardboard panel, pull the relay block off the side of the black compressor dome, and gently shake it. If it rattles like crushed gravel, the internal ceramic disc has shattered and must be replaced.
Inverter Compressors (Samsung & LG Models)
Modern Samsung (Digital Inverter) and LG (Linear Inverter) refrigerators do not use traditional PTC start relays. Instead, they use Variable-Frequency Drive (VFD) electronic boards that send 3-phase modulated AC power directly to the compressor.
When an inverter refrigerator clicks or stops running, technicians inspect the diagnostic LED light on the main power PCB. Rapid flashes indicate specific inverter faults (e.g., Samsung SPM overcurrent or LG IPM error codes). We test phase-to-phase winding balance across all three pins.
Frequently Asked Questions
Rather Have an Expert Fix It Today?
Our EPA Section 608 certified technicians carry all replacement fans, defrost heaters, valves, and boards directly in their trucks. Arrival in under 2 hours across Garland.